You are here: Ceramic breaks>Vacuum breaks

More options

Events Go
Catalogue Go
Special offers Go
New products Go
Focus on Go
Partner Go
partner
Represented Companies Go
Vacuum breaks

Fig.1

Fig.2

Fig.3

Technical information
Voltage (kV DC) Fig. Flange A B C P/number
5 1 CF16 74 25 19.05 1-BE-0885
15 1 CF16 92 25 19.05 1-BE-0857
30 1 CF16 117 25 19.05 1-BE-0880
5 1 CF40 67 42 31.75 1-BE-0858
30 1 CF40 107 42 31.75 1-BE-0859
60 1 CF40 160 42 31.75 1-BE-0886
5 2 KF16 74 25 19.05 1-BE-0887
15 2 KF16 92 25 19.05 1-BE-0860
30 2 KF16 117 25 19.05 1-BE-0881
5 2 KF40 67 42 31.75 1-BE-0861
30 2 KF40 107 42 31.75 1-BE-0862
60 2 KF40 160 42 31.75 1-BE-0888
10 3 Weld 39 12.90 7.87 1-BE-0889
20 3 Weld 65 30.48 22.86 1-BE-0890
30 3 Weld 85 60.32 50.80 1-BE-0891
40 3 Weld 111 71.12 60.96 1-BE-0892
10 1 CF16 47 16.51 7.87 1-BE-0893
20 1 CF40 76 35.56 22.86 1-BE-0867
30 1 CF63 102 63.50 50.80 1-BE-0868
40 1 CF100 122 76.20 60.96 1-BE-0882
10 3 Weld 92 60.19 58.67 1-BE-0875
10 3 Weld 91 96.77 95.25 1-BE-0876
20 3 Weld 114 154.43 152.40 1-BE-0877
20 3 Weld 118 198.88 196.85 1-BE-0878
10 1 CF63 114 82.04 58.67 1-BE-0863
10 1 CF100 117 107.95 95.25 1-BE-0864
20 1 CF160 140 175.76 152.40 1-BE-0865
20 1 CF200 146 223.52 196.85 1-BE-0866
Specifications
Voltage: up to 60kV DC
Material:
Flanges: Stainless steel
Insulation: Alumina ceramic
Vacuum range (UHV/HV): 1x10-10 mbar / 1x10-8 mbar
Temperature range:
CF & weldable FT -200 to 450°C
Iso-K mounted FT -20 to 150°C

 Various transitions in vacuum systems require voltage isolation. Breaks and envelopes are all suitable for ultra high vacuum environments. Both are constructed using a high purity alumina insulator sealed into stainless steel or Kovar® sleeve adapters.

Vacuum breaks are available with nominal tube diameters up to 203.2 mm, and voltage ratings up to 90,000 volts DC. Standard designs include CF flanged, KF flanged and weldable.

 Custom design available upon request. Please contact our sales office.